Jogging in place. Evaluation of a simplified exercise test.

  1. N Papazoglou,
  2. E Kolokouri-Dervou,
  3. I Fanourakis,
  4. P Natsis, and
  5. P Koutsiouba
  1. Department of Cardiology, Third Hospital of Social Security, Athens, Greece.

Abstract

The purpose of this study was to evaluate jogging in place as an electrocardiographic exercise test. Jogging in place continuously recorded via an ordinary single-channel electrocardiograph was compared with the Bruce treadmill protocol with a three-channel monitor and recorder in 141 cases with a wide spectrum of chest complaints. Agreement for the presence or absence of electrocardiographic ischemia (ST-segment displacement greater than or equal to 1 mm at 80 ms from the J point, or U-wave inversion) for the two tests was observed in 91 percent of the cases (95 percent confidence intervals: 86 percent to 95.5 percent). One hundred of the previous cases with paired electrocardiographic exercise tests were compared with the presence of reversible defects on exercise myocardial thallium-201 scintigraphy. The electrocardiographic ischemia had a similar correct classification rate in both methods (83 percent with jogging in place and 85 percent with Bruce treadmill protocol; not significant) against the finding of scintigraphic ischemia. This was also true for 52 cases having selective coronary arteriography. The correct classification rate was 54 percent (28/52) with jogging in place and 48 percent (25/52) with Bruce treadmill protocol (not significant). Given the safety and the easy applicability, even in older persons, this simplified test can be recommended as a valid alternative to the established multistage exercise tests.

« Previous | Next Article »Table of Contents