Chest
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vigneswaran, R
Right arrow Articles by Whitfield, J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Vigneswaran, R
Right arrow Articles by Whitfield, J.

Chest, Vol 80, 174-177, Copyright © 1981 by American College of Chest Physicians


ARTICLES

The use of a new ultra-thin fiberoptic bronchoscope to determine endotracheal tube position in the sick newborn infant

R Vigneswaran and JM Whitfield

The various techniques available for determining endotracheal tube position after intubation of a newborn are auscultation of the chest, observation of distance rings on the endotracheal tube, and chest radiology. Radiology is considered to be the most reliable method. We evaluated the use of a new ultra-thin fiberoptic bronchoscope on 20 recently intubated newborn infants to determine the position of the endotracheal tube and compared the technique with radiology. The accuracy of the two methods was comparable (correlation 0.91, P less than 0.001). Adverse changes in transcutaneous PO2 were observed during both procedures but were more marked during radiology than bronchoscopy. We conclude that the bronchoscopic technique of determining endotracheal tube position is both as safe and as accurate as radiologic technique.


This article has been cited by other articles:


Home page
CLIN PEDIATRHome page
K. J. Sullivan, S. R. Goodwin, and R. Jankowski
A Hand-Held, Reusable, Flexible Fiberoptic Catheter to Confirm Correct Endotracheal Tube Placement in Children: An Evaluation and Comparison with Chest Radiography
Clinical Pediatrics, May 1, 2000; 39(5): 303 - 306.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American College of Chest Physicians.