Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lien, W.
Right arrow Articles by Chang, F.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lien, W.
Right arrow Articles by Chang, F.

Chest, Vol 78, 747-752, Copyright © 1980 by American College of Chest Physicians


ARTICLES

Automaticity of subsidiary pacemakers of patients with dysfunction of the sinus node

WP Lien, JJ Chen, TL Wu and FZ Chang

Automaticity (postpacing impulse recovery time) of the sinus node or subsidiary pacemakers (or both) was determined by intracardiac recordings and atrial overdrive pacing in three patients with disease of the sinus node. Their electrocardiographic manifestations included sinus bradycardia, sinoatrial block, sinus arrest, atrioventricular junctional rhythm, and atrioventricular dissociation. One patient, who initially had syncope, demonstrated prolonged time for recovery of the sinus node (maximum corrected value, 3,485 msec) and impaired atrioventricular junctional automaticity (maximum corrected junctional recovery time, 1,460 msec). Of the remaining two patients without syncopal attacks, one had an adequate low atrial or junctional escape mechanism following cessation of pacing. The maximum low atrial escape interval was 1,660 msec, and the maximum junctional recovery time was 1,770 msec (corrected value, 140 msec). The third patient disclosed a prolonged maximum corrected recovery time for the sinus node (870 msec), while the maximum junctional recovery time was only 1,810 msec (corrected value, 160 msec). We conclude that automaticity of the subsidiary pacemakers in disease of the sinus node can be determined in the presence of atrioventricular dissociation or total sinus arrest, and that determination of the recovery time of the subsidiary pacemakers may be useful in identifying symptomatic patients with sinus nodal dysfunction.