Guest Access | Sign In via User Name/Password |
|||||||||
Chest, Vol 76, 543-545, Copyright © 1979 by American College of Chest Physicians
ARTICLES |
JA Corson, JL Grant, DP Moulton, RL Green and PT Dunkel
Two paralyzed patients who were being treated with mechanical respirators and in whom weaning with intermittent mandatory ventilation failed were treated with regular sessions of biofeedback. Their respiratory volumes were displayed to them on oscilloscopes at bedside. A plastic (Plexiglas) template was placed on the face of the oscilloscope with two horizontal strips of adhesive tape affixed to it; the patient had to achieve a certain tidal volume (TV) to push the tracing outside the space between the horizontal lines. During each session the highest TV achieved determined the target TV to be maintained during the next session. The application of treatment coincided with improved ventilation; both patients were eventually weaned.
This article has been cited by other articles:
![]() |
J. E. Holliday and M. Lippmann Reduction in Ventilatory Response to CO2 With Relaxation Feedback During CO2 Rebreathing for Ventilator Patients Chest, October 1, 2003; 124(4): 1500 - 1511. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Holliday and C. Veremakis Reduction in Ventilator Response to CO2 With Relaxation Feedback During CO2 Rebreathing in Normal Adults Chest, May 1, 1999; 115(5): 1285 - 1292. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |