To determine if simple maneuvers that occur in daily life, such as changes in body position and isometric handgrip exercise, affect Doppler-derived measurements of diastolic function, we studied 22 normal male subjects in the supine position at rest and during several postural manipulations and during handgrip exercise. Comparison of values obtained in the 80 degrees upright tilt position with those obtained in the standard supine position revealed significant decreases in early diastolic flow velocity (peak E) (-25 +/- 3 percent; p less than 0.001), late diastolic flow velocity (peak A) (-9 +/- 3 percent; p less than 0.01), and the ratio of early to late flow velocities (E/A ratio) (-17 +/- 4 percent; significant increases in deceleration time (+55 +/- 10 percent; p less than 0.001) and isovolumic relaxation time (+38 +/- 4 percent; p less than 0.001). Comparison of values obtained with supine isometric exercise with those obtained during the preceding supine resting state revealed significant decreases in peak E (-12 +/- 3 percent; p less than 0.001) and the E/A ratio (-21 +/- 4 percent; p less than 0.001) and significant increases in peak A (+15 +/- 4 percent; p less than 0.001) and isovolumic relaxation time (+16 +/- 3 percent; p less than 0.001). The response of Doppler-derived measurements of diastolic function to postural changes and isometric exercise is complex and multifactorial. Interpretation of these measurements must take into account changes in loading conditions.
This article has been cited by other articles:
![]() |
L. Shmuylovich and S. J. Kovacs Load-independent index of diastolic filling: model-based derivation with in vivo validation in control and diastolic dysfunction subjects J Appl Physiol, July 1, 2006; 101(1): 92 - 101. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. W. Roest, W. A. Helbing, P. Kunz, J. G. van den Aardweg, H. J. Lamb, H. W. Vliegen, E. E. van der Wall, and A. de Roos Exercise MR Imaging in the Assessment of Pulmonary Regurgitation and Biventricular Function in Patients after Tetralogy of Fallot Repair Radiology, April 1, 2002; 223(1): 204 - 211. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |